Chiller Rental

Chiller C2R096 – 92 kW

Chiller_C2R096

Chiller C2R-096 – 92 kW

The C2R-096 chiller offers a cooling capacity of 92.42 kW at a flow temperature of 15 °C and a return temperature of 20 °C. The system uses the modern refrigerant R454B and requires a 400 V / 3-phase / 50 Hz electrical connection. The monthly rental price is available on request.

C2R-096 Chiller – 92 kW chiller for industrial process cooling and room air conditioning

The chiller C2R-096 is a powerful, air-cooled chiller for industrial process cooling and room air conditioning. With a Cooling capacity of 92.42 kW (at a flow temperature of 15 °C) and a wide Temperature range from −10 °C to +30 °C is this unit ideal for a wide range of applications. This is due to its specifications, which include a hermetic scroll compressor and two axial fans on the condensing side.
The C2R-096 has been developed for reliable use in industry, machine cooling and technical processes. Thanks to its robust design and integrated hydronic circuit, this chiller is particularly well suited to applications where high operational reliability and precise cooling are required. The technical basis for this is provided by the scroll compressor, an integrated 250-litre buffer tank and an integrated pump with an available operating pressure of 2.73 bar.

Chiller for a wide range of cooling applications

Whenever production processes, machinery, or technical installations require reliable cooling, the C2R-096 demonstrates its strengths. The chiller can produce chilled water or glycol mixtures at temperatures ranging from −10 °C to +30 °C. This makes the unit particularly well suited for applications where specific process temperatures must be maintained consistently. The relevant operating data are documented in the data sheet, with the rated output under standard conditions (12 °C to 7 °C) being 78.95 kW.
Typical areas of application include industrial process cooling, machinery and plant cooling, and space air conditioning in combination with air handling units (AHUs). In addition, the unit is frequently used for technical cooling in production environments or as temporary hire refrigeration during maintenance, refurbishment, or failure of existing systems.

Robust refrigeration technology for industrial use

The C2R-096 is designed as an air-cooled chiller and is equipped with two axial fans. The air-cooled design simplifies integration into existing installations and makes the unit particularly attractive for temporary and mobile applications. With an air volume flow of 31,000 m³/h per fan, the chiller ensures reliable heat dissipation even under demanding operating conditions. Thanks to the quick-release water connections (Camlock DN50) and the 63 A CEE plug, the unit can be installed and commissioned rapidly.
At the same time, operation remains at a very good level for this performance class, with a sound pressure level of 56.9 dB(A) at 10 metres distance. This is a significant advantage, particularly for deployments in commercial or industrial environments.

High-performance hydraulic circuit with integrated tank

A key advantage of the C2R-096 is the integrated hydronic system. The chiller features a
integrated 250-litre buffer tank

and an integrated pumpwhich delivers a flow rate of 12.21 m³/h (203.5 lpm) at an operating pressure of 2.73 bar. -
This allows the chiller to be integrated quickly and reliably into existing cooling circuits. The heat exchanger is embedded within the internal tank. Particularly in industrial applications where a precisely controlled liquid circuit is critical, this feature is a genuine advantage.

Modern refrigeration technology with R454B

The C2R-096 operates with the modern refrigerant R454B. This refrigerant represents a more future-proof approach for modern refrigeration systems compared to older high-GWP solutions.
For users, this means modern technology, high efficiency (EER 3.07), and a refrigeration system that meets today's standards for professional process cooling.

Technical highlights of the C2R-096

div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Specification
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Value
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Cooling output (15 °C flow temperature / 32 °C ambient temperature)
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
92,42 kW
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Rated output (12 °C to 7 °C / 32 °C ambient temperature)
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
78,95 kW
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Temperature range
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
−10 °C to +30 °C
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Cooling medium
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Chilled water or glycol mixtures
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Compressor
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Hermetic scroll compressor
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Buffer tank
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Integrated, 250 litres
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Flow rate
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
12,21 m³/h
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Operating pressure
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
2,73 bar
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Design
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Air-cooled with 2 axial fans
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Refrigerant
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
R454B
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Electrical connection
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
400 V / 50 Hz / 3 Ph / PE
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Sound pressure level (at 10 m)

div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
56,9 dB(A)
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
Weight
div]:min-w-[4em] [&>div]:max-w-[390px] [&>div]:text-sm [&>div]:text-[var(--text-primary)] [&>div]:whitespace-pre-wrap [&>div]:break-words [tr:first-child_&>div]:font-medium" data-slate-node="element">
1,475 kg (operating), 1,225 kg (empty)
All values are based on the data sheet and technical specifications of the C2R-096.

Typical areas of application of the C2R-096 chiller

The C2R-096 is particularly well suited for industrial cooling processes, machinery cooling, and space air conditioning (in conjunction with AHUs). It is also frequently used for temporary refrigeration supply during overhauls or as a replacement and emergency cooling solution in the event of existing system failures.

Hire the chiller C2R-096

The chiller C2R-096 is the right choice when reliable hire refrigeration is required for process cooling or air conditioning. Thanks to its solid industrial design, high cooling output, and integrated hydronic system, this chiller is suited both for temporary deployments and planned hire projects.